SDG1000 User Manual 53
Figure 2- 43 Table 2- 21 Menu Explanations of Waveform Sweep (Page 1/2)
Sweep
Frequency Setting
Use start freq and stop freq or center freq and freq span to set the range of
the frequency. Press the button again to switch between each other.
Figure 2- 44 Table 2- 22 Menu Explanations of Waveform Sweep (Page 2/2)
Function
Menu
Settings
Explanation
Swp Time
Set the time span of the sweep in which
the frequency changes from the start
frequency to stop frequency.
Stop Freq
Freq Span
Set the stop frequency of the sweep;
Set the frequency span of the sweep.
Start Freq
Mid Freq
Set the start frequency of the sweep;
Set the center frequency of the sweep.
Source
Internal
Choose internal source.
External
Choose external source, use the [Ext
Trig/Gate/FSK/Burst] connector in the
rear panel.
Manual
Set the start and stop time by hand.
Function
Menu
Settings
Explanation
Trig Out
Open
Off
Set signal triggered at rise edge;
Turn off trigger setting.
Linear/
Log
Set the sweep with linear spacing;
Set the sweep with logarithmic spacing.
Direct
Sweep upward;
Sweep downward.