SDG1000 User Manual 99
3.7. Example 7:Generate a Sweep Linear Wave
Generate a sine sweep waveform whose frequency starts from 100Hz to
10kHz. Use internal trigger mode, linear sweep, and the sweep time is 2s.
Steps:
Set the sweep function:
Press Sine and choose the sine waveform as the sweep function.
The default setting of the source is internal.
Set the frequency, amplitude and offset.
1. Press Freq and choose Freq which will display in white color. Input 5
from the keyboard and choose the unit kHz to set the frequency 5kHz.
2. Press Ampl to choose Ampl which will display in white color. Input 5 from
the keyboard and choose the unit Vpp to set the amplitude 5Vpp.
3. Press Offset to choose Offset which will display in white color. Input 0
from the keyboard and choose the unit Vdc to set the offset 0Vdc
Set the sweep time.
Press Sweep Sweep Time, Input 2 from the keyboard and choose the
unit s to set sweep time 2s.
Set the start frequency
Press Start Freq, Input 100 from the keyboard and choose the unit Hz
to set start freq 100Hz.