Converting to LP Gas (continued)
Step 5
Check for Leaks
When all connections have been made, make sure all
range controls are in the off position and turn on the
main gas supply valve. Use a liquid leak detector
at all joints and connections to check for leaks in the
system.
l CAUTION: DO NOT USE A FLAME TO CHECK /
]
FOR GAS LEAKS. !
When using test pressures greater than 1/2 psig to
pressure test the gas supply system of the residence,
disconnect the range and individual shut-off valve
from the gas supply piping. When using test pres-
sures of 1/2 psig or less to test the gas supply sys-
tem, simply isolate the range from the gas supply
system by closing the individual shut-off valve.
Step 6
Convert Top Burner Valves
NOTE: Only valves with these types of
knobs are adjustable.
1. Turn all of the top burners to LOW.
2. Remove all 4 knobs.
3. With a smal! flat blade _.
screwdriver, turn the "_._.. /
valve set screws clock-(_= _ _
wise to decrease flame __
size, counterclockwise to "_ _7'vt
increase flame size_ _ Ill
Adjust until the flame is _"%._'_
about the same height as "_1
the top of the burner, tf
4. Replace the knobs_
5. Check for flame outage by opening and closing the
oven door several times, tf the flame goes out,
increase the flame size.
Step 7
Check Quality of Flames
The combustion quality of burner flames needs to be
determined visually See Installation Instructions sec-
tion "Quality of Flames," Step 5
46