Kenmore 3627536890 gas range

User Manual - Page 45

For 3627536890.

PDF File Manual, 98 pages, Download pdf file

Loading ...
Loading ...
Loading ...
[3 Standard Twin Burner Models
(models with lift-up cooktops)
1, Lift the cooktop
2, Lift the burner
assemblies
straight up and
set aside to gain
access to sur*
face burner
spud&
3. With a 7mm,
5/16" or a small
adjustable
wrench (depend-
ing on the size
needed), remove each of the four spuds on the su_-
face burner gas inlet tubes and replace them with
the correct gas spuds mounted in a holder at the
right rear of the range, above the regulator., Natural
gas spuds are brass and LP gas spuds are red or
silver.. (Mount the spuds that you removed from the
inlet tubes back in the holder..) To prevent leakage,
make sure spuds are securely screwed into gas
inlet tubes.
4. Replace the burner assemblies..
5. Keep all spuds with your range so you have them if
you move or get a different gas hook-up.
Top Burner Orifice Drill Size Color
Natural Gas #54 (°0550 D!,a;,) .....Brass
LP (Propane) #66 (.0330 Diao) Red or Silver
Step 3
Convert the Oven Burner Orifices
Oven Burner
1. Remove oven door, storage drawer or broiler draw-
er and oven bottom. The lower burner orifice spud
is tocated behind the storage drawer, broiler drawer
or kick panel. (On some models, a metal shield
must be removed to access the orifice.)
2. To convert to LP gas, use a
1/2" wrench to turn the lower
burner orifice spud clockwise.
Tighten the spud only until it is
snug. To prevent damage, do
not overtighten the spud.
To convert to natural gas,
loosen the spud about 2 turns.
Broil Burner (on some models)
To convert to LP gas, use a 1/2" wrench to turn the
upper burner orifice spud clockwise. Tighten spud
only until it is snug with the base_ To prevent damage,
do not overtighten spud°
To convert to natural gas, loosen the spud about
2 turns.
Step 4
Convert Air Adjustment Shutter(s)
For LP gas, loosen the Phillips
head screw and rotate the shut-
ter to the full open position. With
baffle in place, flames should
have approximately 1" (2.5 cm)
blue cones and should not
extend beyond the edges of the
burner baffle° After 30 seconds
of burner operation, check for
sc.4
Air
Shutter
flames lifting off burner ports. If lifting is observed,
gradually reduce air shutter opening until flames are
stabilize&
For natural gas, the shutter should be open t/2"
(I.3 cm) or about 3/4 of the way open_
(continued next page)