Loading ...
Loading ...
Loading ...
52
6.1.4 Media Sensor Calibration (for the Black Mark Sensor)
1. Turn off the printer.
2. Select the function you want:
- For TJ-4005DN/TJ-4010TN/TJ-4020TN/TJ-4120TN:
The printer calibrates the Gap Sensor and the Black Mark Sensor simultaneously.
a. Press and hold the Pause button, and then turn on the printer.
b. Release the button when the Power LED lights, and the printer feeds the labels.
- For TJ-4021TN/TJ-4021TNR/TJ-4121TN/TJ-4121TNR:
a. Press and hold the right Selection button, and then turn on the Power Switch.
b. Release the button when Bline Calibration appears on the Touchscreen.
Note
The LED color will change as follows:
Amber (lit) red (5 times) amber (5 times) green (5 times) green/amber (5 times)
red/amber (5 times) green (lit)
6.1.5 Media Sensor Calibration (for the Gap Sensor)
1. Turn off the printer.
2. Select the function you want:
- For TJ-4005DN/TJ-4010TN/TJ-4020TN/TJ-4120TN:
The printer calibrates the Gap Sensor and the Black Mark Sensor simultaneously.
a. Press and hold the Pause button, and then turn on the printer.
b. Release the button when the Power LED lights, and the printer feeds the labels.
- For TJ-4021TN/TJ-4021TNR/TJ-4121TN/TJ-4121TNR:
a. Press and hold the right Selection button, and then turn on the Power Switch.
b. Release the button when Gap Calibration appears on the Touchscreen.
Note
The LED color will change as follows:
Amber (lit) red (5 times) amber (5 times) green (5 times) green/amber (5 times)
red/amber (5 times) green (lit)
Loading ...
Loading ...
Loading ...