146
R-410A SEALED SYSTEM REPAIR
Replace 24k Outdoor unit Compressor and Motor
Step
Important: Befor e disassembly
and assembly, mak e sure that the power to the system
has been disconnected and veriļ¬ed as voltage free.
Illustration
Handling Instruction
1.Remove external casing
2.Remove motor
1. Remove the top cover, handle
and valve cover;
2. Remove the outer case and
right side plate.
3.Remove compressor
1. Remove the blade nut and
then remove the blade;
2. Remove the motor from
motor supporter
4. Assemble unit
Assemble the unit in the
reverse order of disassembly.
1. Reclaim the refrigerant from
the entire system.
2. Unsolder the 4 -way valve
piping assy from compressor;
3. Remove the compressor
mounting bolts;
4. Carefully remove the
compressor from chassis.
Loading ...
Loading ...