- 31 -
4.3.2 TANK THERMOSTAT REPLACING
Remove the metal cover sheet in the rear side of the cabinet, as
already explained at paragraph 2.3 and 2.5.
Inside the tank remove the product spacer grill (27), unscrewing the
8 screws highlighted in fig. 53 and the sensor plastic support (74),
marked with "S" in fig. 54, loosening the 2 screws marked with "V".
Remove the insulating material from the access hole of the
thermometer and thermostat sensors, marked with a circle in fig.
55. Pull outwards the thermostat sensor. In this position the sensor
is coated by a transparent sheath, marked with an arrow in fig. 55.
Release the thermostat from its seat, removing the front grill (26)
and control panel (18) unscrewing the two fastening screws as
already explained in fig. 12, 13, 14 and 15 in paragraph 2.4:
extract the adjusting knob (fig. 56) and loosen the nut highlighted
in fig. 57.
Introducing the new thermostat, be careful to insert the sensor in
the appropriate position in the compressor compartment and pay
attention to secure the sensor by means of the bearing clamps, as
par fig. 58.
FIG. 53
FIG. 54
FIG. 55
FIG. 57
FIG. 56