Part 5 - Appendix
109
Camera WebSetup Connection
Access the WebSetup of the camera which is internal VIN
network from the PC.
Port Forward through 2 routers "NVR Port Number
and HTTP Port Number of the Camera"
Eth 0: WAN Port : 16001
Eth 1: VIN IP : IP address of the camera
Eth 1: VIN Port : HTTP port number of the camera
Approach
You can access the WebSetup page through the
following address.: http://NVR IP address: HTTP Port
Number of the Camera/setup/setup.html
Enter the HTTP port number of the camera 16001 to
have port forwarded.
IDIS Web Connection through IDIS
Camera
Access the IDIS Web of the camera which is internal VIN
network from the PC.
Port Forward through 2 routers "NVR Port Number
and HTTP Port Number of the Camera"
Eth 0: WAN Port : 16001
Eth 1: VIN IP : IP address of the camera
Eth 1: VIN Port : HTTP port number of the camera
Port Forward through 2 routers "NVR Port Number
and Remote Port Number of the Camera"
Eth 0: WAN Port : 11002
Eth 1: VIN IP : The IP address of the camera
Eth 1: VIN Port : Remote port number of the camera
Eth0 port number and the remote port number
of the camera must be same.