2N TELEKOMUNIKACE a.s., www.2n.cz 20/134
Cut a circular hole in the wall of the diameter of 103 mm and depth of 50 mm before
installation. It is assumed that all necessary cables of the maximum length of 25 cm
will lead to the hole. Put the flush mounting box in the hole to make sure that the hole
is deep enough. If the hole complies with the box size, wall in the box and level the
box using a water level on the holding clips. When the mortar hardens, break off the
Use anchoring elements to fix the clips and cap the box with the cover provided.
device into plasterboard.
Downloads
Drilling template.pdf
Use a 2.5 mm hexagon key wrench (included in the delivery) for 2N Indoor Compact
®
fitting into the flush mounting box.2N Indoor Compact
®
Note
While flush mounting respect the local standards 2N Indoor Compact
®
concerning installation of electronic devices on flammable materials.