User’s Manual
21
camera sends closing signal. The boom gate does not enter the fleet mode when it opens
after receiving opening command from the connected camera.
Set H-31 to 0, and when the boom gate is opened, press and hold Open on the remote
control for 4 seconds to enter the fleet mode.
H-33 define the up and down limits according the defined speed
After powering on the boom gate for the first time, it needs to find the limit of the gate before it
can enter the normal working mode.
The controller supports three limit finding modes:
0: Find both up limit and down limit. Press Open, the boom rises. The motor stops after the
boom finds the up limit. Press Close, the boom falls. The motor stops after the boom finds
the down limit. After both up and down limits are found, the boom gate enters the normal
working mode.
1: After powering on the controller for the first time, press Open, the boom rises. The boom
gate enters the normal working mode after it finds the up limit. The motor will stop. If you
press Close after first-time power-on, the boom rises. The boom gate enters the normal
working mode after it finds the up limit. The boom gate will be closed in normal working
mode.
2: After powering on the controller for the first time, press Close, the boom falls. The boom
gate enters the normal working mode after it finds the down limit. If you press Open after
first-time power-on, the boom gate closes first, finds the down limit, and then it can open
in the normal working mode. This mode is ideal for scenes blocked with eaves.
H-34 adjust the up and down limits manually
You can use this command to manually set the up and down positions of the boom, so that it is
more intuitive to adjust the up and down positions of the boom.
After entering the H-34 command, the LED shows L-00, and then the boom falls. After the
boom finds the down limit, the buzzer beeps, and the LED changes to L-01. Then the boom
rises, the buzzer beeps, and the LED changes to L-02, meaning that the up limit has been
found. At this moment, the gate stops, and you need to manually find the vertical and
horizontal positions of the boom:
1) Press and hold Close, the boom works in the closing direction, until it is in the required
vertical position.
2) Press Settings to confirm the vertical position, then the LED shows L-03, meaning that
the boom gate finishes finding the vertical position.
3) Continue to press and hold Close until the boom is in the desired horizontal position.
4) Press Settings to confirm the horizontal position. After you hear the sound from the
buzzer, the boom gate goes back to the normal working status.
If the boom does not reach the desired position after manual adjustment, you can press
Open or Close to adjust the position. During the adjustment process, if you do not release
the Open or Close button when the boom reaches the up or down limit, the controller will
stop the motor, and the buzzer makes continuous buzzes for alarm.
If H-33 is set to 0, the boom gate can work normally after manual adjustment. If H-33 is set
to 1, the parameters manually adjusted are saved, and they will take effect only when H-33
is set to 0.
The parameters adjusted through H-34 will influence F-08 and F-09. You can view the
adjustment value of horizontal and vertical positions through F-08 and F-09.