Select one of the options, and then press Settings, the parameters of F-00 to F-07 are
automatically modified, and H-33 is automatically changed to 1. If the speed does not meet the
on-site requirements, you can fine-tune the parameters of F-00 to F-07.
This option can reduce the difficulty of on-site commissioning and reduce the commissioning
time.
H-03 automatic delay closing after vehicle passes
The range of H-03 is 0–255 (0 by default). Unit: 1 second. Different from F-10, H-03 means that
the countdown starts after the vehicle passes the coil or radar.
If there is an opening command during the countdown, the timer will be reset.
If the boom gate receives closing command, it will close immediately.
If it receives stop command, it will stop delay.
If the value is set to 0, the function will be turned off, and the boom gate closes after the
vehicle passes.
H-07 counting function
In some cases, the boom gate closes only when the number of opening times matches with the
closing times of ground sense relay. 0 means turning off the function. The value indicates the
maximum number of consecutive opening times.
H-08 automatic test
Interval of automatic aging test. 0 means the function is turned off. After the test is complete,
set this parameter to 0, or press Stop during the opening or closing process to exit automatic
test.
H-09 restore factory default settings
To prevent improper operation, set the parameter to 10, and then press Settings to restore
default settings. After the operation is complete, if you hear one buzz, the operation was
successful; and if it is 2 buzzes, the operation failed.
After restoring default settings, restart the device to make the settings take effect.
H-17 traffic light changes when the boom opens to the defined angle
When the boom gate opens to the defined angle, the relay of the traffic light interface changes
from COM and Red shorted to COM and Green shorted. After connecting to the traffic light
power supply, the traffic light interface can adapt to traffic lights of any voltage.
Traffic light wiring Figure 3-8
H-31 enter the fleet mode when opening the boom gate by remote control
Setting H-31 to 1 means that after opening the boom gate by remote control, it enters fleet
mode (the boom gate keeps open until a specified amount of vehicles pass), until you close
the boom gate. You can exit the fleet mode by remote control, or when the connected