TROUBLESHOOTING INSTALLATION & CUSTOMER SERVICE INFORMATION
Is your beverage not dispensing?
a) Before ordering a service components (found at the end of this guide) for a nitro system, please check bullet points “b)” -
“k)” and conrm your lines are properly setup according to Operation 12.
b) Check if beverage kegs are empty.
c) Ensure the beverage kegs lid is properly shut. The lid should be parallel to the ground if installed properly (should not
be angled).
d) Check the regulator to see if the nitrogen tank is empty.
e) Ensure nitrogen tank and all necessary gas lines are set to an open position. Unused, open gas lines will cause the
beverage to dispense improperly and cause a safety hazard since nitrogen is being released.
f) Tug each beverage and gas line by its connection to ensure a secure connection.
• If the tubing is sliding o the hose barb during the check, cut the tubing and reapply it to the hose barb. Ensure a hose
drive clamp is rmly axed and compressing the tubing to the barb.
g) Remove and reapply the quick disconnects to ensure they are properly attached.
h) Using an adjustable wrench, ensure the hex nut that attaches the regulator to the tank is rmly attached.
i) Ensure there are no beverage leaks by checking inside the refrigeration unit. Also, listen for any hissing or high-pitched
noises to conrm there are no gas leaks.
j) Check to see if uid is owing in and out of the nitrogen infuser.
• If uid ow can not be resolved through this troubleshooting process, proceed to the last step.
k) Reach out to customer support at [email protected] or (800)438-8898 for any additional questions.