14
PERLICK NITRO BEVERAGE DISPENSING KIT
Operation/Installation Manual
1. Attach a new beverage line and a red gas line from the air
distributor to the input hose barbs on the nitrogen infuser.
The inputs will say gas & beverage. (Fig. 9)
a) If the dual infuser is being used, repeat
Step 1 for the other two inputs.
b) Place a worm drive clamp around the tubing before
connecting to the hose barb.
c) Ensure to never have a smaller bend radius than 2
inches during installation.
d) Remove the connector on the beverage lines
connected to the input.
2. Repeat Step 1, however attach new beverage lines to
output(s). One output for single and two for dual. These
lines will later be connected to the tower (Fig. 8).
a) If the tower does not have a threaded connection,
remove the connector.
WARNING
Never apply more than a two-inch bend
radius to beverage tubing.
3. Attach the infuser to the cabinet via a phillips screwdriver
and the four black screws provided in the nitrogen infuser’s
packaging to the mounting holes drilled in Operation 1.
OPERATION #4
NITROGEN INFUSER INSTALLATION
Fig. 8
Single infuser inputs
Dual infuser inputs