13
Form No. Z2751
Rev. 05.26.21
PERLICK NITRO BEVERAGE DISPENSING KIT
Operation/Installation Manual
INTERNAL NITROGEN TANK MOUNTING
1. Place the tank, regulator, and air distributor inside the
refrigeration unit (Fig. 4) to determine length of gas tubing
in Step 2.
2. Cut the red gas tubing to the desired length based on
where the components will be located.
3. Route the red gas tubing to the regulator (Fig. 5) and to
the air distributor (Fig. 4). Attach the tubing to the hose
barb with a hose-drive clamp via a 1/4” hex nut. Ensure it is
compressing the tube and hose barb.
4. Attach the regulator to nitrogen tank via an adjustable
wrench. Rotate the hex tting (Fig. 5) until the it can no
longer be rotated.
a) Make sure to use teon tape on all pressurized,
threaded connections.
EXTERNAL NITROGEN TANK MOUNTING
1. For an external nitrogen source, identify the knockouts
location and remove it.
2. Cut the red gas tubing to the desired length based o of
where the external nitrogen tank is located.
3. Place the air distributor inside the refrigeration unit and
route the red gas tubing through the knockout hole.
4. Attach the routed red gas tubing to the air distributor (Fig.
1) and regulator (Fig. 5) to barbed ttings and secure the
tubing in place with worm-drive clamps and a 1/4” hex nut
driver or nut driver (Reference Fig. 5 to observe installed
components).
5. Ensure the knockout hole is sealed (with the provided
sealant).
6. Attach regulator to nitrogen tank via an adjustable wrench.
Rotate the hex tting (Fig. 5) until the it can no longer be
rotated.
a) Make sure to use teon tape on all pressurized,
threaded connections.
OPERATION #3
NITROGEN TANK INSTALLATION
All Components shown are reference only
Gas tubing
to regulator
Fig. 4
Fig. 6
Exterior nitrogen
tank install
Interior
nitrogen tank
install
Fig. 5
Regulator
Nitrogen
tank
Hex
tting
Fig. 7
WARNING
Regulator in
kit can only
handle an inlet pressure of 4000
psig. Deviations from this
regulator or exceeding the
tank’s capacity could result in
personal or property damage.