DS-2TD2xxx-xxxx/xx Thermal and Optical Bi-Spectrum Network Camera User Manual
UM DS-2TD2xx-xxxx/xx Thermal 072020NA 13
Chapter 3 Temperature Measurement
When you enable this function, the device measures the actual temperature of the scene. It alarms when
the temperature exceeds the temperature threshold value.
3.1 Notice
This part introduces the notices of configuring temperature measurement function.
The target surface should be as vertical to the optical axis as possible. It is recommended that the
angle of oblique image plane should be less than 45°.
The target image pixels should be more than 5 × 5.
If multiple presets will be taken for temperature measurement, it is recommended to set the patrol
time above 20 s.
Select line thermography or area thermography for a certain area temperature measurement. The point
thermography is not recommended in case of deviation occurring during device movement to affect
temperature measurement accuracy.
3.2 Thermography Configuration Flow Chart
This section introduces temperature measurement configuration.