Friedrich 1198788 Floating Air Series 24000 BTU Dual Zone Mini Split System with 2x 9000 BTU Wall Mounted Unit and Outdoor Unit

User Manual - Page 176

For 1198788.

PDF File Manual, 244 pages, Read Online | Download pdf file

1198788 photo
Loading ...
Loading ...
Loading ...
176
COMPONENTS TESTING
Field Settings (Indoor Unit Parameter Revision)
PARAME TE R
C O DE
PARAME TE R
DESC R IPTIO N
NO TE
PARAME TE R VALUE &R EPR ES ENTATIO N
DATA
TYPE
REPR ESE NTATIO N
(FUNC TIO N C O D E )
1
Integer
Self Recovery of
Power Break
2 Integer Temperature Type
0Cancel Self Recovery of Power
Break function
1Self Recovery of Power Break
othersinvalid
3
Integer
Temperature Display
Type
0Centigrade Temperature
1Fahrenheit Temperature
othersinvalid
4
0Default display set temperature
1Default display room temperature
othersinvalid
Integer
Ratio of ambient
temperature sensed
by indoor
temperature
sensor(cooling
mode)
0~10valid more than 10 default is10
00% 110% 10100%
5
Filter Clean
Indication
Integer
0-entirely use
temperature
sensed b y wired
remote controller;
10-entirely use
temperature
sensed b y indoor
unit
6 Integer Filter Clean Time Set
0Cancel Filter Clean prompt function
1Set Filter Clean prompt function
othersinvalid
7
0~32 more than 32 default is 32*1000h
Integer
Installation Height
Compensation
8
Integer
0~10m more than 10m default is 10.
=0,1,2 :no fan speed compensation;
=3: increase fan speed;
=4~10: increase more fan speed.
Cooling Temperature
Compensation
indoor unit
temperature sensor
9
Integer
00°C ; 1-0.5 °C;2-1°C
3-1.5 ºC; 4-2ºC; 5: -2.5ºC;
Heating Temperature
Compensation
indoor unit
temperature sensor
10 Integer Static Pressure Set
00°C;1-0.5 °C;2-1°C
3-1.5 °C 4-2°C;5-2.5 °C;
6-3°C7-3.5 °C; 8: -4°C; 9: -4.5°C
10-5°C ( the wired controller displays
intege r with the symbol )
Duct type (DC
motor )
12 Integer
1~240 function code=static pressure
more than the limit static pressure
default the limit static pressure Default
is 0( default static pressure,
related to
models )
Ratio of temperature
sensed by indoor
temperature
sensor( (Heating
mode)
0~10valid more than 10 default is10
00% 110% 10100%
13
Charac
0-entirely use
temperature
sensed b y wired
remote controller;
10-entirely use
temperature
sensed b y indoor
unit
ter
Temperature
Adjustment-Cooling
-10~10 Sing le Ch aracter with
symbol
14
Temperature
displayed on wired
controller
Charac
ter
Temperature
Adjustment-Heating
-10~10 Sing le Ch aracter with
symbol
25
Temperature
displayed on wired
controller
Integer
Access control, fire
protection, ON/OFF
function set
=0 Access control, fire
protection functions are all invalid
=1 Access control function is valid
=2 fire protection function is valid
=3 Access control, fire protection are
all valid
=4 ON/OFF function are all valid.
6 : -3ºC; 7: -3.5ºC; 8: -4°C; 9: -4.5°C
10: -5°C (The wired controller displays
integer with the symbol.)