Majestic 500DVMNSC Direct Vent Natural Gas Fireplace

User Manual - Page 26

For 500DVMNSC.

PDF File Manual, 68 pages, Read Online | Download pdf file

500DVMNSC photo
Loading ...
Loading ...
Loading ...
26
75D2525
DVM Series Direct Vent Gas Fireplace
Termination
Cap
Storm Collar
Roof Sup-
port
Flashing
Rigid Pipe
Length
Flex to Pipe
Adapter
Firestop
UL1777 Flex
PIpe
Figure 38 -
Typical Vertical Flex Vent Installation
Screws
(3 Places
equidistant
just above
gear clamp)
Rigid Pipe Length
Flex to Pipe Adapter
Gear Clamp
1C\v" Flexible Pipe and
Adapter Outer Collar Over-
lap
UL1777 Flex Vent
Figure 39 -
Typical Pipe Connection
Gear Clamp
Screws
(3 Places equidistant
just above gear clamp)
Gear Clamp
UL1777 Flex Vent
1C\v" Flexible Pipe
and Collar Overlap
MHSC Horizontal
Vent Termination
Figure 40 -
Typical Horizontal Flex Vent Installation
DVFF8A/8 5" x 8"
to 5" x 8" Adapter
FP1974

2. Install restop spacers, Figure 38, when penetrat-
ing ceiling, attic spaces, or walls.
3. Do not allow the exible vent to bend in radius
tighter than 5" (127 mm). Figure 37
4. Horizontal runs of exible vent shall be supported
at maximum 2 foot intervals; vertical runs, ve feet
intervals. Metal strapping, properly secured, is an
acceptable means to support the exible vent.
5. Flexible vent spacers are to be installed at inter-
vals prescribed by the exible vent manufacturer;
and in such a way as to maintain concentric inner
and outer vent spacing.
D. Attaching exible venting to vertical termination
assemblies.
1. When using 5 x 8 ex pipe, an MHSC ex-to-pipe
adapter and/or rigid pipe section(s) is required to
connect the exible vent assembly to the verti-
cal termination by using three self-penetrating
screws.
2. Review Figure 39 and corresponding instruc-
tions for proper overlap, clamp and screw place-
ment.
3. Three each self-penetrating screws are drilled
opposite one another and below the gear
clamp.
4. Use only listed and approved terminations and
accessories, installed per the installation instruc-
tions and Figure 38.
E. Installing exible venting to horizontal termination
assemblies.
1. Connect the 5" exible vent to the horizontal
termination as in Figure 40.
2. Connect the 8" exible vent to the termination
ring as in Figure 40.
3. Review Figure 40 for proper overlap and clamp
placement.
4. Three each self-penetrating screws are drilled
opposite one another and below the gear lamp.
5. Use only listed an approved terminations and
accessories, installed per the termination instruc-
tions and Figure 40.