Majestic 500DVMNSC Direct Vent Natural Gas Fireplace

User Manual - Page 18

For 500DVMNSC.

PDF File Manual, 68 pages, Read Online | Download pdf file

500DVMNSC photo
Loading ...
Loading ...
Loading ...
18
75D2525
DVM Series Direct Vent Gas Fireplace

HOT
Figure 17 -
Install Horizontal Vent Cap
Vent Cap
Wood Screw
Apply Mastic to
All Sides
FP1955

      

HOT
Figure 18 -
Installing Vinyl Siding Standoff and Termination
Apply Mastic to All Sides
Cut Vinyl Siding Away to Fit Standoff
or Termination
Wood Screw
Termination
Bolt
Nut
Standoff #1250 or 5DT-VS
(Not Required for MHSC
Termination)
FP1956



Figure 19 -
Connect Vent Cap with Horizontal Vent Pipe
Interior Wall
Surface
Fire Stop
Assembly
Horizontal
Vent Pipe
Screw
Vent Cap
(Horizontal
Termination)
FP1957



         
     
       


The Vent Graph, showing the relationship between vertical
and horizontal side wall venting, will help to determine the
various dimensions allowable. Refer to Page 15.


(Exception: Outside wall with
restop: 1" all around pipes are allowed)
Z\x

When vent termination exits through foundations less than
20" below siding outcrop, the vent pipe must ush up with
the siding.
It is best to locate the replace in such a way that minimizes
the number of offsets and horizontal vent length.
The horizontal vent run refers to the total length of vent
pipe from the ue collar of the replace (or the top of the
transition elbow) to the face of the nished outside wall or
the mounting ange of the termination.


No other manufacturer's termination
is pemitted in this application.

6. Slide the wall thimble over the vent pipe before con-
necting the horizontal run to the vent cap. Figure 19
7. Carefully move the fireplace with vent assembly
attached toward the wall and insert the vent pipe into
the horizontal termination. The pipe overlap should
be a minimum of 1Z\v". Apply silicone to the outer pipe
connection. Fasten all vent connections with screws
provided.
8. Slide the wall thimble against the interior wall surface
and attach with screws. Figure 19