Display Operating Procedure
Description
First installat.
DISABLED/ENABLED
• This parameter allows the operator to
reactivate the rst installation message
to the next power of the machine.
NOTE: Ensure all air is removed from the
group prior to staring the espresso
machine.
“Machine OFF” Programming
1
Enter into “Machine Off” programming mode.
2
Scroll through the displayed parameters using the button until the following display appears:
3
Press the button or the button to change the value between DISABLED or ENABLED.
4
When nished, press the button to continue to the next parameter.
Language
ENGLISH
First installat.
DISABLED/ENABLED
OFF 09:30
First Installation