Display Operating Procedure
Description
TEST SAFETY VALV
DISABLED/ENABLED
• This parameter allows the service staff
to enable/disable the safety valve test.
• This parameter allows to bring the
steam boiler temperature to 140°C, thus
triggering the safety valve. Once the
valve has triggered disable the function.
• Should the safety valve fail to trigger
within approximately one minute of the
temperature reaching 140°C, disable
the function and replace the valve.
• Only qualied technicians can perform
this operation.
“Machine OFF” Programming
1
Enter into “Machine Off” programming mode.
2
Scroll through the displayed parameters using the button until the following display appears:
3
Press the button or the button to change the value between DISABLED or ENABLED.
4
When nished, press the button to continue to the next parameter.
Language
ENGLISH
TEST SAFETY VALV
DISABLED/ENABLED
OFF 09:30
Safety Valve