Napoleon NZ3000H1 High Country 3000 Series Fireplace

User Manual - Page 35

For NZ3000H1.

PDF File Manual, 120 pages, Read Online | Download pdf file

NZ3000H1 photo
Loading ...
Loading ...
Loading ...
EN
W415-2044 / C / 08.20.21
35
operation
8.2 bypass door
Ensure bypass door is open during startup and re-
fueling. See above for bypass door rod location.
Pull bypass rod outwards.
When hot, use tool provided.
12
34
Press bypass rod downwards then inwards to lock into
place.
Open fi rebox doors and load fuel.
The bypass door is an internal mechanism that allows the exhaust products to travel through an obstrusive path
to the fl ue prior to engaging the catalyst.
The bypass door is operated by pulling the bypass rod located on the right side of the appliance out and down
until it catches and remains open. To shut the bypass door, pull the rod out and up allowing the rod to slowly
retract into the appliance. Be sure not to allow the bypass door to slam shut.
The bypass pull handle tool must be used with your appliance for adjusting the bypass rod. This tool will prevent
injury as the bypass rod becomes extremely hot as the appliance heats up. When you receive your appliance,
the bypass rod tool will come unassembled. It can be easily assembled by screwing the spiralled handle onto the
body of the tool.