nishing
Blower Fan
Connections
- Removing the
junction box cover
on the blower
exposes 3 coloured
wires:
One black wire
- connects to power
“L2” (neutral lead).
One green wire
- connects to
ground.
One white wire
- connects to the
fan-speed control, rheostat, or wall switch, or thermostat.
VENT CONNECTION
D. Connect the 6” (152mm) liner to the 6”(152mm) appliance collar and blower collars. Secure using 3 screws on
each end and seal with caulking. Liner stretches to a maximum of 10’ (3m).
GRILL AND FILTER INSTALLATION
E. Insert the fi lter into the grill. Foam gasket (1/2” [13mm] weather stripping) between the grill and blower housing
is recommended, but not supplied. The blower fi lter is washable. The bottom lip of the grill latches over the
bottom lip of the housing. Use two screws to secure the top of the grill to the facing material.
For complete installation instructions, refer to the blower kit.