installation
4.0 installation
!
WARNING
Never install a single wall slip section or smoke pipe in a chase structure. The higher temperature of this single
wall pipe may radiate suffi cient heat to combustible chase materials to cause a re.
To avoid danger of fi re, all instructions must be strictly followed, including the provision of air space clearance
between chimney system and enclosure. To protect against the effects of corrosion on those parts exposed to
the weather, we recommend that the chase top be painted with a rust-resistant paint.
Maintain a minimum 2” (51mm) air clearance to all parts of the chimney system at all times. Failure to maintain
this 2” (51mm) air clearance will cause a structure fi re.
Detailed instructions for installation of the chase top, storm collar and termination cap are packaged with these
parts.
Firestop spacers must be used whenever the chimney penetrates a ceiling/ oor area.
The chimney must be sound and free of cracks. Clean your chimney a minimum of twice a year and as
required.
Always seal penetrations with temperature rated sealing products.
4.1 chimney
This appliance was tested to CAN/ULC S610 and UL 127 Factory Built Fireplace Standards. This appliance has
met the test criteria for Zero Clearance Installation to Combustible Surfaces and certifi ed to burn fi rewood only.
Any 7” (177.8mm) diameter chimney listed to these standards may be installed. In accordance with these
standards, the appliance may also be connected to any chimney listed to CAN/ULC-S604 and CAN/ULC-S629
for Canada or UL-103HT for the United States.
Installation of all types of factory-built chimney systems is to be in accordance with the chimney manufacturer’s
installation instructions. An appropriate chimney manufacturer’s anchor base plate is required in order to initiate
their system. An anchor base plate gasket is supplied
that suits a 7” (177.8mm) chimney. Use the high
temperature gasket (supplied) to seal between the
anchor plate and the appliance top.
For complete installation instructions, refer to
instructions provided with the manufactured chimney
system.
A chimney venting the appliance shall not vent any
other appliance. The minimum overall chimney height
from the top of the appliance is 15ft (4.6m). The
maximum overall chimney height from the top of the
appliance is 34ft (10.4m).
Factory-built chimney systems for use in dwellings
constructed for three or more families must be enclosed above the room in which the appliance is located. This
enclosure must have a fi re resistance rating equal to or greater than that of the fl oor or roof assembly through
which they pass.
The chimney should not be built with an offset angle in excess of 45° in Canada and 30° in USA. Ensure that
minimum clearances are maintained.
Portions of the chimney that extend through accessible spaces must always be encased to avoid personal
contact with the chimney and thereby avoid damage to the chimney.
The chimney must be supported at a maximum of 20ft (6.1m) intervals. Every 20 ft (6.1m) of chimney can weigh
up to approximately 200lbs (90.7kg). Refer to chimney manufacturer’s specifi cations.
All venting connections must be in compliance with the chimney manufacturer’s installation instructions.
note:
ANCHOR PLATE
ANCHOR PLATE GASKET
APPLIANCE TOP
ANCHOR PLATE FOR A FACTORY