20
Care and Cleaning
Cleaning the Control Panel
The display and touch panel may be wiped with a
damp clean cloth, as needed. Do not use chemicals
or any abrasive materials. Be careful not to use
sharp objects that may damage the surface of the
touch panel or displays.
Plexiglass Door Window
You may use a mild glass cleaner and a soft cloth to
remove finger prints on the Plexiglass door window.
Do not use a razor blade, chemicals or abrasives.
Exterior Stainless Steel Surfaces
CAUTION
Always wipe stainless steel (silver colored) surfaces with
the grain.
Clean stainless steel surfaces with a mild solution
of detergent and warm water. Rinse and dry with a
soft, lint-free cloth. You may also use Dacor Stain-
less Steel Cleaner. Use it according to the directions
on the package.
Changing/Replacing the Clean-
Pour Head Gasket
The Clean-Pour head is designed to provide ease of
use and cost effective replacement when damaged.
To replace the head gasket:
1. Locate the threaded nut on the bottom of the
head assembly. Un-thread and remove it by
turning it in a counter clockwise direction. If it is
difficult to turn, you may use needle-nose pliers.
Be careful not to damage the plastic threads.
2. Remove gasket from stem.
3. Select the gasket color to be used (green, red or
white).
4. After placing the gasket onto the stem, carefully
thread the nut back onto the stem by turning
clockwise. It should thread easily. IMPORTANT:
Do not force. Make sure the nut is secure.
Gasket
Gasket
nut