TROUBLESHOOTING
Malfunction of Temperature Sensor F1, F2
Indoor unit
(1) Malfunction of Temperature Sensor F1, F2
Main detection points:
Is the wiring terminal between the temperature sensor and the controller loosened or poorly contacted?
Is there short circuit due to trip-over of the parts?
Is the temperature sensor broken?
Is mainboard broken?
Malfunction diagnosis process:
Start
Is the wiring terminal between the
temperature sensor and the controller
loosened or poorly contacted?
Insert the temperature
sensor tightly
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
Is malfunction
eliminated
Is malfunction
eliminated
Is malfunction
eliminated
Make the parts upright
Replace it with a
temperature sensor with
the same model
Is there short circuit due to trip-
over of the parts
Is the temperature sensor normal
according to the resistance table?
Replace the mainboard with
the same model.
End