COMPONENTS TESTING
Figure 706
36k Outdoor Unit Printed Circuit Board Identification
Top view
Bottom view
No. Name No. Name No. Name
1 High-frequency transformer T1 6 High pressure protection terminal HPP1 11 Terminal of neutral wire
2
Overload protection terminal of
compressor OVC-COMP
7 Terminal of 4-way valve 12 Protective tube FU101
3 Terminal of temp sensor CN2 8 Electric heater band of chassis HEAT2-L 13 Terminal of ground wire
4
High pressure protection terminal
HPP
9
Electric heater band of compressor
HEAT1-L
14 Choke L 101 and L102
5
Electronic expansion valve terminal
EV
10 Terminal of live wire 15
Terminal of outdoor fan
OFAN-DC
1 2 3 4 5 6
7
8
9
10
11
12
13
1415
Loading ...
Loading ...
Loading ...