• !A: Performs logic "NOT" operation on the waveform voltage values of the
specified sources point by point and displays the results. In operation, when the
voltage value of the source channel is greater than the threshold of the
corresponding channel, it is regarded as logic "1"; otherwise it is logic "0". The
results of logic "NOT" operation of one binary bit are shown in
Table 9.2 Logic
Operation
.
Table 9.2 Logic Operation
A B A&&B A||B A^B !A
0 0 0 0 0 1
0 1 0 1 1 1
1 0 0 1 1 0
1 1 1 1 0 0
Operation Result Display Window
Click or tap the Operation on/off switch to enable or disable the display of the
operation result window. The source and the waveform sizes parameters are
displayed at the top of the window, as shown in the figure below.
Figure 9.11 Operation Result Display Window
Source
Click or tap the drop-down button of SourceA or SourceB to select CH1, CH2, CH3,
or CH4. When a source channel is selected, the selected channel automatically
switches to the ON state.