Samsung AC078BNPDBC/TC 8.0 HP Floor Standing Inverter

User Manual - Page 32

For AC078BNPDBC/TC. Also, The document are for others Samsung models: AC078BNPDBC

PDF File Manual, 76 pages, Read Online | Download pdf file

AC078BNPDBC/TC photo
Loading ...
Loading ...
Loading ...
32
English
Deciding on where to install the product
INSTALLATION PARTS
Outdoor unitOutdoor unit
Sea breezeSea breeze
SeaSea
If you cannot avoid installing the outdoor unit by the seashore, construct a protection wall around to
block the sea breeze.
Protection wall
Outdoor
unit
Sea breeze
Sea
Protection wall should be constructed with a solid material
such as concrete to block the sea breeze and the height and
the width of the wall should be 1.5 times larger than the size
of the outdoor unit. Also, secure over 700mm between the
protection wall and the outdoor unit for exhausted air to
ventilate.
Install the outdoor unit in a place where water can drain smoothly.
If you cannot find a place satisfying above conditions, please contact manufacturer. Make sure to
clean the sea water and the dust on the outdoor unit heat exchanger and spread corrosion inhibitor
on heat exchanger. (At least one time per one year.)
Choose a place where there is no direct sunlight.
Choose a place where it could not come into contact with snow and rain.
Choose a place where flammable gas does not leak.
Choose a place where the indoor and outdoor unit can be connected with a pipe.
Choose a place where there is no direct sunlight.
Choose a place where it could not come into contact with snow and rain.
Choose a place where flammable gas does not leak.
Choose a place where the indoor and outdoor unit can be connected with a pipe.
WARNING
After installing the outdoor unit, apply rust inhibitor on the internal pipes and heat exchanger.
If you don’t apply rust inhibitor, airborne corrosive gas (such as sulfur compounds, hydrogen sulfide
and ammonia) and salty dust may cause pipe corrosion which will lead to refrigerant leakage.
Inspect the outdoor unit at least once a year and re-apply the rust inhibitor where it is damaged
(worn out).
When applying the rust inhibitor, please be aware of the following:
Turn off the power before spraying the rust inhibitor.
Wear protective goggles and mask before spraying.
Clean the dusty surface with clean fabric or paper before spraying.
Make sure that wind is blowing from workers back when spraying.
Do not spray on the PCB panel and electric parts.