117
Top Toolbar
The top toolbar contains various function buttons with options for operations and
configurations of the MaxiScope, the operations of which are described in the table below:
Table 17-1 Toolbar Buttons
Button
Name
Descriptions
Print
Saves and prints a copy of the displayed data.
Tool
Tapping this button opens a settings window with
options to configure various measurement tools
for reference and assessment of data analysis:
Tap Select a Math Channel to select a
match channel.
Tap Select a Probe to select a predefined
probe.
Tap Cache Setting to set the cache.
Save
Tapping this button opens a submenu, on which 5
options will display, allowing you to save, record,
and play back the waveform data.
Tap Save current page to take a screenshot
image.
Tap Record data to save the current
waveform data.
Tap Save Ref to save a copy of an existing
signal waveform as reference.
Tap Review data allows selecting and
reviewing the previously stored waveform
recordings.
Tap Recall Ref to retrieve the saved
reference waveforms.
All saved images are stored in the Data Manager
application for later reviews. See
Image.
Help
Provides instructions or tips for operations of
various functions.
Loading ...