©2021 Sharp NEC Display Solutions, Ltd. Page 46 of 86
Disable (Default) – Power to the Compute Module will remain on even when the display is in
standby mode.
6.6 Slot Compute Module Power Setting Power Supply Off
Delay
Available options: adjustable between 30600 seconds
This sets the time delay after the Shutdown Signal is set until the power to the Compute Module is turned
off. Configure this to allow adequate time for any software to shutdown safely.
Note that a monitoring utility must be installed to watch the GPIO 23 shutdown signal.
Note: For use only when the AUTO SHUTDOWN is set to ENABLE.
6.7 Slot Compute Module Power Setting Auto Display Off
Available options: Enable / Disable
Allows the display to switch into standby power save mode when the Compute Module signals that it has
transitioned into shutdown via the RUN_PG signal. Note that this signal is only output from the Compute
Module if the following settings are made to the Compute Module 4’s EEPROM:
WAKE_ON_GPIO=0
POWER_OFF_ON_HALT=1
Please see the documentation from Raspberry Pi for instructions on how to change the Compute
Module’s EEPROM settings.