Siglent SDG7032A 350 MHz Arbitrary Waveform Generator

Manual - Page 91

For SDG7032A.

PDF File Manual, 133 pages, Read Online | Download pdf file

SDG7032A photo
Loading ...
Loading ...
Loading ...
SDG7000A User Manual
84 / 133 WWW.SIGLENT.COM
Application example: 10 kHz sine waveform as thecarrier, with a burst output
every 10 ms, each burst containing 5 periods
1. Set "Waveform" of the carrier to "Sine" and "Frequency" to 10 kHz in the parameter
setting page of the carrier.
2. Enter the Modulation/Sweep/Burst settings and set "Burst" to "On"
3. Set "Type" to "NCycle"
4. Set "Source" to "Internal"
5. Set "Burst Period" to 10 ms
6. Set "Cycles" to 5
7. Set "Trig Out" to "Up", turn on the trigger output. Use the rising edge of the trigger
output to trigger the oscilloscope to steadily capture the burst signal
8. Turn on the channel output and observe the results
Follow these steps to generate the desired burst signal. The burst parameters page after the
setup is shown below.
Loading ...
Loading ...
Loading ...