Siglent SDG7032A 350 MHz Arbitrary Waveform Generator

Manual - Page 87

For SDG7032A.

PDF File Manual, 133 pages, Read Online | Download pdf file

SDG7032A photo
Loading ...
Loading ...
Loading ...
SDG7000A User Manual
80 / 133 WWW.SIGLENT.COM
Trigger source = internal, trigger output = on
1. Set the carrier "waveform" to "Sine" in the CH1 carrier parameter setting page
2. Enter the modulation/sweep/burst settings and set "Sweep" to "On"
3. Set "Type" to "Linear"
4. Set "Source" to "Internal"
5. Set "Sweep Time" to 3 ms
6. Set "Start Hold Time", "End Hold Time", "Back Time" to 0 s
7. Set "Direction" to "Up"
8. Set "Start Freq" to 100 Hz and the “Stop Freq” to 100 kHz
9. Turn on the trigger output. Use the rising edge of the trigger output to synchronize
with the start frequency and use it to trigger the oscilloscope to observe a stable
sweep signal
10. Turn on the output of CH1 and observe the result
11. Change the "Type" to "Log" and observe the results
Follow these steps to generate the desired sweep signal. Once set up the linear sweep
parameters page is as follows. The parameters for the logarithmic sweep differ only in the “Type"
field.
The results of the sweep output are as follows: (red traces are sweep signals, blue traces are
trigger signals).