Step
One segment is output at each trigger, and each segment is output in
sequence.
Advanced
Jump from one segment to any other , and the trigger conditions of a
jump can be set (refer to table 9.11 Trigger mode).
Table 9-13 Marker
Description
Maker Setting
Marker output, synchronous output at the specified segment, and point
Save/Recall
Save the current sequence settings as a file (*.awg), or load a saved sequence file. For the
operation instructions of save/recall see the chapter "Save/Recall".
Application example: Output a sequence with the following segments in turn.
ï‚Ÿ Waveform = Sine, 32768 points, 2 Vpp, repeat once
ï‚Ÿ Waveform = Square_Duty50, 32768 points, 1 Vpp, repeat twice
ï‚Ÿ Waveform = UpRamp, 32768 points, 2 Vpp, repeat 3 times
1. On the carrier parameter setting page, open the "Sequence" function.
2. Enter the "Sequence" setting, and the device will automatically call the Sequence Editor.
3. Click the waveform preview area to specify the data source of segment 1, select
"Source" as "Built-In" in the subsequent data source selection interface, select "Sine"
in the directory of "wave Type" = "Common", and return to the Sequence Editor.
4. Set the number of repeat to 1.
5. Set amplitude to 2 Vpp and offset to 0 V.
6. Click Add to add segment 2.
7. Set the waveform and parameters of segment 2 according to the similar operations in
steps 3 ~ 5.
8. Click Add to add segment 3.
9. Set the waveform and parameters of segment 3 according to the similar operations in
steps 3 ~ 5.
10. Click the “Running/Stopped" button to start the sequence playback.
11. Open the output.
The following figure shows the actual output waveform: