6. Use the same method to generate the data file and download it to CH2 of the device.
7. Set the “Interpolation” of the two channels to "0-order hold" on the device.
8.
Set the amplitude and rate of the clock and data output on the device as required. For
example, to set the clock frequency to 1 MHz set the "Sample Rate" of the clock
channel to 2 MSa/s. Since the clock and data are synchronized, CH1 and CH2 can be
set as frequency coupling with a ratio of 1 (Read the section "Channel Track/
Coupling/Copy" for the setting method). In this way, only the rate of one channel
needs to be set, and the rate of the other channel can be updated synchronously. The
clock and data signals finally output by the device are as follows:
The waveform generated by EasyWaveX can be saved as a csv file for further
editing. After editing, it can be imported into EasyWaveX and loaded to the
device through EasyWaveX. You can also store the csv file to the USB flash
disk, and the device can recall it directly from the USB flash disk.