DIAGNOSTICS & TROUBLESHOOTING

NOTE: The Service Diagnosc Mode must be acvated before
performing the tests; see procedure on page 2-3.
: Turn o power or disconnect washer/dryer
before aaching test leads. Be sure test leads are aached
prior to component acvaon.
To check voltage measurements, the following steps must be
followed:
1. Unplug washer/dryer or disconnect power.
2. Connect voltage measurement equipment to appropriate
connectors.
3. Plug in washer/dryer or reconnect power and conrm
voltage reading.
4. Aer performing voltage measurements, unplug washer/
dryer or disconnect power
From the DIAGNOSTICS HOME screen:
3$*(
< DIAGNOSTICS HOME
Error Diagnostic
Clear Error History
Figure 1
Scroll down and select “Component Acvaon”
3$*(
Clear Error History
System Info
Component Activation
WiFi
Figure 2
Connued on following page . . .
For Service Technician Use Only
Voltage Measurement Safety Information
When performing live voltage measurements, you must do the following:
n Verify the controls are in the off position so that the appliance does not start when energized.
n Allow enough space to perform the voltage measurements without obstructions.
n Keep other people a safe distance away from the appliance to prevent potential injury.
n Always use the proper testing equipment.
n After voltage measurements, always disconnect power before servicing.
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before operating.
DANGER
Electrical Shock Hazard
Only authorized technicians should perform
diagnostic voltage measurements.
After performing voltage measurements,
disconnect power before servicing.
Failure to follow these instructions can result in
death or electrical shock.