4 RELEASE
Sets the time from when HOLD is passed to when the volume level becomes 0.
The minimum value is 0. The maximum value is 127. When the parameter 4 adjustment knob is turned clockwise even further from the maximum
value, the value becomes [INFINITY].
The default is 0.
5 TRIGGER MODE
How the envelope operates in response to a trigger can be set. This can be selected from the two options [One Shot] and [GATE].
One Shot:
[A] l [H] l [R] are passed with the on trigger, regardless of the length of time that the performance pad is pressed.
GATE:
[A] l [H] l [R] are passed while the performance pad is pressed. When [H] is [INFINITY], moves to [R] with the off trigger.
This is suitable for synthesizer sound and other sound that is sustained.
6 SETTING
The AMP ENVELOPE settings can be changed.
[Attack Curve]:
The curve of ATTACK can be changed. It can be switched to [Linear] or [Curve].
[Release Curve]:
The curve of RELEASE can be changed. It can be switched to [Linear] or [Curve].
7 SYNC
Whether or not to link the operation of ENVELOPE with the BPM can be set.
The default is OFF.
Applying effects to tracks (FX1)
Effects can be inserted in tracks.
SELECT FX button
Tapping the [SELECT FX] button displays the FX list.
Turn the rotary to select and then press the rotary selector to enter the
selection.