Installation
www.bora.com
2
1
Fig. 10.35 Inserting the lter replacement cover
[1] Filter replacement cover
[2] Inlet opening
X Inside the inlet opening push the filter
replacement cover until it comes to a stop in the
filter housing opening.
X Check that the filter replacement cover is
positioned correctly.
10.8 Connecting the power
supply
X Observe all safety and warning information
(see „2 Safety“).
X Observe all national and regional laws and
regulations as well as the supplementary
regulations of the local utility companies.
i
The appliances may only be connected to the
mains power supply by certified specialists.
The specialist also assumes responsibility for
the proper installation and commissioning.
i
Connections via plug-in contacts (Schuko
plugs) are not permitted.
i
1-phase connection The appliance complies
with the requirements of IEC 61000-3-12.
Fig. 10.36 Suction chamber locks
X Open the 5 suction chamber locks.
Fig. 10.37 Removing the bottom of the suction
chamber
X Remove the bottom of the suction chamber.
X Switch off the main switch/automatic circuit
breaker before connecting the cooktop.
X Secure the main switch/automatic circuit
breaker against being switched back on without
permission.
X Make sure the power to the appliance is
disconnected.
X Connect the cooktop exclusively via a fixed
connection to an H 05 VV-F power supply cable
with corresponding minimum cross-section (see
Table 10.2).