Technical Data
TECHNICAL DATA
Camera nameCamera name
Leica S3
Camera typeCamera type
Digital medium format SLR camera
Type no. Type no.
6847
Lens mountLens mount
Leica S bayonet with contact strip for communication between lens and
camera
Lens systemLens system
Lens systemLeica S lenses, compatible with several third-party medium
format lenses via adapter
Picture format/Aspect ratioPicture format/Aspect ratio
30 x 45mm/3:2
Picture sensor/ResolutionPicture sensor/Resolution
Leica CMOS sensor with 4.6µm pixel size, with micro lenses, 64MP
Low-pass filterLow-pass filter
None (for maximum sharpness), suppression of moiré effects due to
external digital image processing on the sensor
File formatsFile formats
Photo: DNG (raw data), DNG + JPG, JPG
Resolution DNG: 64MP, JPG: 64MP, 24MP, 4MP
File sizeFile size
DNG: approx. 70MB, JPG: approx. 2-30MB (depending on resolution
used, image content and ISO level), video: up to 29minutes of uninter-
rupted recording
Buffer memoryBuffer memory
2GB, maximum number of pictures in a series (depending on memory
card used): DNG: max. 6, JPG: unlimited
Color spacesColor spaces
Adobe® RGB, sRGB, ECI RGB 2.0
White balanceWhite balance
Automatic, manual via measurement, 8 presets, color temperature input
Storage mediumStorage medium
CF cards (max. UDMA7), SD-/SDHC-/SDXC <512GB memory cards
UHS-I (recommended), UHS-II, 4K video recordings can only be stored on
SD cards (UHS-I).
Menu languagesMenu languages
English, German, French, Italian, Spanish, Russian, Japanese, Traditional
Chinese, Simplified Chinese, Korean, Portuguese
Exposure control
Exposure meteringExposure metering
Open aperture measurement through the lens (TTL)
Metering methodsMetering methods
Spot (3.5%), center-weighted, multi-field metering (5 fields)
Metering memory lockMetering memory lock
Pressing the pressure point on the shutter button saves 1 picture or
continuously with the joystick
Exposure compensationExposure compensation
±3EV (exposure values), adjustable in half increments
Automatic bracketingAutomatic bracketing
3 or 5 pictures, optionally 1⁄2EV, 1EV, 2EV, 3EV deviation between
individual pictures, exposure can be changed through the aperture and/
or shutter speed depending on the selected operating mode
Measuring rangeMeasuring range
(with 2.5 aperture and ISO100), Spot metering: EV2.7 - 20, Center-
Weighted and Multi-Field metering: EV1.2 - 20, warning in viewfinder if
the measuring range of the measuring cell for the existing multi-field
photo diode light is exceeded or falls below the range (continuous light
measurements)
SensitivitySensitivity
ISO100, ISO200, ISO400, ISO800, ISO1600, ISO3200, ISO6400,
ISO12500, ISO 25000, ISO 50000, automatic
Exposure modesExposure modes
automatic program with program shift function
( ), aperture priority mode ( ), shutter priority mode ( ), manual setting
( )
Flash exposure control
Flash unit connectorsFlash unit connectors
Accessory shoe with central and control contacts, LEMO® or standard
flash jack without light output control
SynchronizationSynchronization
Flash sync time: 1⁄125s or 1⁄1000s for lenses with central shutter,
slower shutter speeds can be used, optionally at the start or end of the
exposure; Flash function with faster shutter speeds (1⁄180s – 1⁄4000s)
available with relevantly equipped flash units (HSS mode)
Flash measuring cellFlash measuring cell
Multi-field photo diode
Flash exposure metering/controlFlash exposure metering/control
(with system-compatible Leica flash units attached to the camera)
Controlled by the flash unit with TTL pre-flash metering, including
automatic transfer and consideration of the sensitivity and set/controlled
lens, all of the exposure modes can be used, automatic adjustment of the
flash light to the existing light
Linear flash modeLinear flash mode
(with system-compatible, appropriately equipped Leica flash units, linear
flash mode with TTL pre-flash metering and automatic TTL HSS control)
For flash photography with shorter shutter speeds than the sync speed by
firing several flashes in quick succession, automatic switch-over to HSS
flash mode if the sync speed is not achieved
Stroboscope flash modeStroboscope flash mode
(Taking pictures while recording video)
With exposure modes P and A including automatic adjustment of the
exposure time with system-compatible, relevantly equipped Leica flash
units
Flash exposure compensationFlash exposure compensation
Setting option in relevantly equipped flash units
Displays in flash modeDisplays in flash mode
Ready status indicated by flashing or constantly lit flash icon in the
viewfinder
Focusing
Sharpness recognitionSharpness recognition
Phase detection process in Live View mode based on contrast
Sensor/metering fieldSensor/metering field
A central cross-type sensor defined by cross hairs on the focusing
screen; the metering field can be positioned freely in Live View mode
Flash modesFlash modes
Optional AFs (single) = focus priority, AFc (continuous) = release priority,
MF (manual), manual override of the automatic setting at any time
Metering memory lockMetering memory lock
Pressing the pressure point on the shutter button saves 1 picture or
continuously with the joystick
Autofocus driveAutofocus drive
In lenses
Viewfinder system
EyepieceEyepiece
High eye point viewfinder, diopter correction adjustable from -3 to +1dpt.
on the viewfinder
ViewfinderViewfinder
98%
MagnificationMagnification
0.87times with 70mm lens, when set to infinity and 0dpt.