The plug used for the connection must comply with standards and be suitable for the appliance's
power
absorption.
If the appliance is connected directly to the mains, an omnipolar circuit breaker with contact gap of at
least 3 mm, rated for the load and compliant with the relevant regulations, must be installed between
the appliance and the mains.
) Never use reducers, adapters or diverters for the mains connection, since they may
overheat and cause burns.
) The appliance must be earthed. The manufacturer declines all liability for failure to
comply with this requirement. ( Fig. 20 )
When replacing the power lead, use a cable with the same characteristics as the original, suitable for
the load and the temperature (such as T90°C) involved; the replacement must be ordered from the
service centre. At the end of the cable for connection to the appliance, the green-yellow earth wire
must be 20 mm longer than the other wires.
Refer to the table below for power lead dimensions.
Hob type Size
Gas burners only
3X0.50mm
2
H05 V2V
2
-
F
With 1000W electric plate
3 X 0.75 mm2
H05 V2V2-F
With 1500W electric plate or two electric plates
3 X 1,5 mm2
H05 V2V2-F
Barbecue
3 x 1.5 IMQ
H05 VV-F
Fryer
3 x 1.5 IMQ
H05 RN-F
THE MANUFACTURER ACCEPTS NO LIABILITY IN CASE OF FAILURE TO COMPLY WITH THE
ABOVE INSTRUCTIONS
AND WITH NORMAL ACCIDENT PREVENTION STANDARDS.