Cleaning and care
154
Mainentance
The Ready at and Start at functions are
not available in Maintenance .
Soak
Heavy soiling can be soaked with this
program after a roasting program.
Let the oven cavity cool down.
Remove all accessories from the
oven.
Fill the water container.
Select Maintenance| Soak.
The soaking process takes approx.
10minutes.
Drying
Residual moisture in the oven compart-
ment is dried, even in inaccessible ar-
eas.
Dry the oven cavity with a soft cloth
first.
Select Maintenance| Drying.
The drying process takes approx. 20
minutes.
Rinsing
During this process the water-carrying
system is rinsed out. Any remaining
food deposits are flushed out of the
system.
Select Maintenance| Rinse.
Follow the instructions in the display.
Rinsing takes approx. 10minutes.
Descaling
We recommend that you use Miele
Descaling Tablets (see "Optional ac-
cessories") for descaling the appli-
ance. They have been specifically de-
signed for optimal descaling of Miele
products. Other descaling agents,
which - in addition to citric acid - may
contain other acids and/or other unde-
sirable substances such as chlorides,
might damage the product. Also, the
desired effect cannot be guaranteed if
the descaling solution does not have
the required concentration.
Descaling solution is acidic.
Do not spill descaling agent onto
metal surfaces. This can cause
marks to appear.
However, should any descaling
agent get onto these surfaces, wipe
it away immediately.
The steam oven needs to be descaled
after a certain number of operating
hours. When the steam oven needs to
be descaled, a number will appear in
the display indicating the number of
cooking processes remaining before the
appliance locks out. Only cooking pro-
cesses using steam are counted. After
the last remaining steam cooking
process, the appliance will lock out.
We recommend that you descale the
appliance before it locks out.
During the descaling process, the water
container must be rinsed out and re-
filled with fresh water and the conden-
sate container must be emptied.