Loading ...
Loading ...
Loading ...
15
ELECTRICAL REQUIREMENTS
MYR65 (Rigid Mount Washing Machine)
Capacity
lbs
RPM
Voltage
(V)
Motor &
Control
Current
During
Max
Draw
Heat
1P
/3P
Total
Amps
(A)
North American
Models
Models Outside of North
America
Electric
kw / Amps
Hot
Water
or
Steam
Electric
(kW)
Amps
(A)
Circuit
Breaker
(D-Curve)
Con-
ductor
Size
Circuit
Breaker
(D-Curve)
Fuse
(Slow
Blow)
Con-
ductor
Size
This appliance is intended to be connected to a supply circuit protected by an over current-protective drive (fuse breaker) sized
according to the "Circuit Breaker (D-Curve)" column appropriate to your location.
Capacity
lbs
RPM
Voltage
(V)
Motor &
Control
Current
During
Max
Draw
Heat
1P
/3P
Total
Amps
(A)
North American
Models
Models Outside of North
America
Electric
kw / Amps
Hot
Water
or
Steam
Electric
(kW)
Amps
(A)
Circuit
Breaker
(D-Curve)
Con-
ductor
Size
Circuit
Breaker
(D-Curve)
Fuse
(Slow
Blow)
Con-
ductor
Size
65 693
100 27.46 X1P 27.46 35 8403
28
110 24.96 X1P 24.96 30 10 32 25 10
115 23.87 X1P 23.87 30 10 32 25 10
120 22.88 X1P 22.88 30 10 32 25 10
127 21.62 X1P 21.62 30 10 32 25 10
200 13.73 X1P 13.73 20 12 20 16 12
208 13.2 X1P 13.2 20 12 16 10 14
220 12.48 X1P 12.48 15 14 16 10 14
230 11.94 X1P 11.94 15 14 16 10 14
240 11.44 X1P 11.44 15 14 16 10 14
208 2.93 13.5 37.53 3P 40.46 63 50 6
220 2.77 15.1 39.69 3P 42.46 63 50 6
230 2.65 16.5 41.5 3P 44.15 63 50 6
240 2.54 18 43.3 3P 45.84 63 50 6
380 1.6 15.1 22.93 3P 24.53 32 25 10
400 1.52 16.7 24.14 3P 25.66 32 25 10
415 1.47 18 25.04 3P 26.51 32 25 10
440 1.39 15.1 19.85 3P 21.24 32 25 10
480 1.27 18 21.65 3P 22.92 32 25 10
Loading ...