ELECTRICAL REQUIREMENTS
MYR25 (Rigid Mount Washing Machine)
Capacity
lbs
RPM
Voltage
(V)
Motor &
Control
Current
During
Max
Draw
Heat
1P
/3P
Total
Amps
(A)
North American
Models
Models Outside of North
America
Electric
kw / Amps
Hot
Water
or
Steam
Electric
(kW)
Amps
(A)
Circuit
Breaker
(D-Curve)
Con-
ductor
Size
Circuit
Breaker
(D-Curve)
Fuse
(Slow
Blow)
Con-
ductor
Size
25 790
100 17.16 X 1P 17.16 25 12 25 20 12
110 15.6 X 1P 15.6 20 12 20 16 12
115 14.92 X 1P 14.92 20 12 20 16 12
120 14.3 X 1P 14.3 20 12 20 16 12
127 13.51 X 1P 13.51 20 12 20 16 12
200 07.8 X 1P 07.8 15 14 16 10 14
208 07.5 X 1P 07.5 15 14 16 10 14
220 07.09 X 1P 07.09 15 14 16 10 14
230 06.78 X 1P 06.78 15 14 16 10 14
240 06.50 X 1P 06.50 15 14 16 10 14
208 01.67 6.0 16.68 3P 18.35 25 20 12
220 01.57 6.7 17.64 3P 19.21 25 20 12
230 01.51 7.3 18.44 3P 19.95 25 20 12
240 01.44 8.0 19.25 3P 20.69 25 20 12
380 00.91 6.7 10.19 3P 11.1 16 10 14
400 00.87 7.4 10.73 3P 11.60 16 10 14
415 00.83 8.0 11.13 3P 11.96 16 10 14
440 00.79 6.7 8.82 3P 09.61 16 10 14
480 00.72 8.0 9.62 3P 10.34 16 10 14
208 01.67 9.0 25.02 3P 26.69 40 32 8
220 01.57 10.1 26.46 3P 28.03 40 32 8
230 01.51 11.0 27.67 3P 29.18 40 32 8
240 01.44 12.0 28.87 3P 30.31 40 32 8
380 00.91 10.1 15.29 3P 16.2 20 16 12
400 00.87 11.1 16.09 3P 16.96 25 20 12
415 00.83 12.0 16.69 3P 17.52 25 20 12
440 00.79 10.1 13.23 3P 14.02 20 16 12
480 00.72 12.0 14.43 3P 15.15 20 16 12
This appliance is intended to be connected to a supply circuit protected by an over current-protective drive (fuse breaker) sized
according to the "Circuit Breaker (D-Curve)" column appropriate to your location.