13
ELECTRICAL REQUIREMENTS
MYR40 (Rigid Mount Washing Machine)
Capacity
lbs
RPM
Voltage
(V)
Motor &
Control
Current
During
Max
Draw
Heat
1P
/3P
Total
Amps
(A)
North American
Models
Models Outside of North
America
Electric
kw / Amps
Hot
Water
or
Steam
Electric
(kW)
Amps
(A)
Circuit
Breaker
(D-Curve)
Con-
ductor
Size
Circuit
Breaker
(D-Curve)
Fuse
(Slow
Blow)
Con-
ductor
Size
40 693
100 26 X 1P 26.00 35 8 32 25 10
110 23.64 X 1P 23.64 30 10 32 25 10
115 22.61 X 1P 22.61 30 10 32 25 10
120 21.67 X 1P 21.67 30 10 32 25 10
127 20.47 X 1P 20.47 25 12 25 20 12
200 13 X 1P 13.00 20 12 16 10 14
208 12.5 X 1P 12.50 15 14 16 10 14
220 11.82 X 1P 11.82 15 14 16 10 14
230 11.3 X 1P 11.30 15 14 16 10 14
240 10.83 X 1P 10.83 15 14 16 10 14
208 2.78 12 33.36 3P 36.14 63 50 6
220 2.62 13.4 35.28 3P 37.90 63 50 6
230 02.51 14.7 36.89 3P 39.40 63 50 6
240 02.41 16.0 38.49 3P 40.90 63 50 6
380 01.52 13.4 20.38 3P 21.90 32 25 10
400 01.44 14.9 21.46 3P 22.90 32 25 10
415 01.39 16.0 22.26 3P 23.65 32 25 10
440 01.31 13.4 17.64 3P 18.95 25 20 12
480 01.20 16.0 19.25 3P 20.45 25 20 12
This appliance is intended to be connected to a supply circuit protected by an over current-protective drive (fuse breaker) sized
according to the "Circuit Breaker (D-Curve)" column appropriate to your location.