ELECTRICAL REQUIREMENTS
MYR30 (Rigid Mount Washing Machine)
Capacity
lbs
RPM
Voltage
(V)
Motor &
Control
Current
During
Max
Draw
Heat
1P
/3P
Total
Amps
(A)
North American
Models
Models Outside of North
America
Electric
kw / Amps
Hot
Water
or
Steam
Electric
(kW)
Amps
(A)
Circuit
Breaker
(D-Curve)
Con-
ductor
Size
Circuit
Breaker
(D-Curve)
Fuse
(Slow
Blow)
Con-
ductor
Size
30 790
100 19.44 X 1P 19.44 25 12 25 20 12
110 17.67 X 1P 17.67 25 12 25 20 12
115 16.90 X 1P 16.90 25 12 25 20 12
120 16.20 X 1P 16.20 20 12 20 16 12
127 15.31 X 1P 15.31 20 12 20 16 12
200 09.72 X 1P 09.72 15 14 16 10 14
208 08.10 X 1P 08.10 15 14 16 10 14
220 07.66 X 1P 07.66 15 14 16 10 14
230 07.33 X 1P 07.33 15 14 16 10 14
240 07.02 X 1P 07.02 15 14 16 10 14
208 01.80 6.0 16.68 3P 18.48 25 20 12
220 01.70 6.7 17.64 3P 19.34 25 20 12
230 01.63 7.3 18.44 3P 20.07 25 20 12
240 01.56 8.0 19.25 3P 20.81 25 20 12
380 00.98 6.7 10.19 3P 11.17 16 10 14
400 00.94 7.4 10.73 3P 11.67 16 10 14
415 00.90 8.0 11.13 3P 12.03 16 10 14
440 00.85 6.7 8.82 3P 09.67 16 10 14
480 00.78 8.0 9.62 3P 10.40 16 10 14
208 01.80 9.0 25.02 3P 26.82 40 32 8
220 01.70 10.1 26.46 3P 28.16 40 32 8
230 01.63 11.0 27.67 3P 29.30 40 32 8
240 01.56 12.0 28.87 3P 30.43 40 32 8
380 00.98 10.1 15.29 3P 16.27 20 16 12
400 00.94 11.1 16.09 3P 17.03 25 20 12
415 00.90 12.0 16.69 3P 17.59 25 20 12
440 00.85 10.1 13.23 3P 14.08 20 16 12
480 00.78 12.0 14.43 3P 15.21 20 16 12
This appliance is intended to be connected to a supply circuit protected by an over current-protective drive (fuse breaker) sized
according to the "Circuit Breaker (D-Curve)" column appropriate to your location.