ELECTRICAL REQUIREMENTS
MYR55 (Rigid Mount Washing Machine)
Capacity
lbs
RPM
Voltage
(V)
Motor &
Control
Current
During
Max
Draw
Heat
1P
/3P
Total
Amps
(A)
North American
Models
Models Outside of North
America
Electric
kw / Amps
Hot
Water
or
Steam
Electric
(kW)
Amps
(A)
Circuit
Breaker
(D-Curve)
Con-
ductor
Size
Circuit
Breaker
(D-Curve)
Fuse
(Slow
Blow)
Con-
ductor
Size
55 693
100 27.04 X 1P 27.04 35 8 40 32 8
110 24.58 X 1P 24.58 30 10 32 25 10
115 23.51 X 1P 23.51 30 10 32 25 10
120 22.53 X 1P 22.53 30 10 32 25 10
127 21.29 X 1P 21.29 30 10 32 25 10
200 13.52 X 1P 13.52 20 12 20 16 12
208 13 X 1P 13.00 20 12 16 10 14
220 12.29 X 1P 12.29 15 14 16 10 14
230 11.76 X 1P 11.76 15 14 16 10 14
240 11.27 X 1P 11.27 15 14 16 10 14
208 2.89 13.50 37.53 3P 40.42 63 50 6
220 2.73 15.1 39.69 3P 42.42 63 50 6
230 2.61 16.5 41.50 3P 44.11 63 50 6
240 2.5 18.0 43.30 3P 45.8 63 50 6
380 01.58 15.10 22.93 3P 24.51 32 25 10
400 01.50 16.70 24.14 3P 25.64 32 25 10
415 01.45 18.00 25.04 3P 26.49 32 25 10
440 01.36 15.1 19.85 3P 21.21 32 25 10
480 01.25 18.0 21.65 3P 22.9 32 25 10
This appliance is intended to be connected to a supply circuit protected by an over current-protective drive (fuse breaker) sized
according to the "Circuit Breaker (D-Curve)" column appropriate to your location.