10
ELECTRICAL REQUIREMENTS
MYR20 (Rigid Mount Washing Machine)
Capacity
lbs
RPM
Voltage
(V)
Motor &
Control
Current
During
Max
Draw
Heat
1P
/3P
Total
Amps
(A)
North American
Models
Models Outside of North
America
Electric
kw / Amps
Hot
Water
or
Steam
Electric
(kW)
Amps
(A)
Circuit
Breaker
(D-Curve)
Con-
ductor
Size
Circuit
Breaker
(D-Curve)
Fuse
(Slow
Blow)
Con-
ductor
Size
20 838
100 11.52 X 1P 11.52 15 14 16 10 14
110 10.47 X 1P 10.47 15 14 16 10 14
115 10.02 X 1P 10.02 15 14 16 10 14
120 09.60 X 1P 9.6 15 14 16 10 14
127 09.07 X 1P 9.07 15 14 16 10 14
200 04.99 X 1P 4.99 15 14 16 10 14
208 04.80 X 1P 4.8 15 14 16 10 14
220 04.54 X 1P 4.54 15 14 16 10 14
230 04.34 X 1P 4.34 15 14 16 10 14
240 04.16 X 1P 4.16 15 14 16 10 14
208 01.07 6.0 16.68 3P 17.75 25 20 12
220 01.01 6.7 17.64 3P 18.65 25 20 12
230 00.96 7.3 18.44 3P 19.4 25 20 12
240 00.92 8.0 19.25 3P 20.17 25 20 12
380 00.58 6.7 10.19 3P 10.77 16 10 14
400 00.55 7.4 10.73 3P 11.28 16 10 14
415 00.53 8.0 11.13 3P 11.66 16 10 14
440 00.50 6.7 8.82 3P 9.32 16 10 14
480 00.46 8.0 9.62 3P 10.08 16 10 14
208 01.07 9.0 25.02 3P 26.09 32 25 10
220 01.01 10.1 26.46 3P 27.47 40 32 8
230 00.96 11.0 27.67 3P 28.63 40 32 8
240 00.92 12.0 28.87 3P 29.79 40 32 8
380 00.58 10.1 15.29 3P 15.87 20 16 12
400 00.55 11.1 16.09 3P 16.64 20 16 12
415 00.53 12.0 16.69 3P 17.22 25 20 12
440 00.50 10.1 13.23 3P 13.73 20 16 12
480 00.46 12.0 14.43 3P 14.89 20 16 12
This appliance is intended to be connected to a supply circuit protected by an over current-protective drive (fuse breaker) sized
according to the "Circuit Breaker (D-Curve)" column appropriate to your location.