9
6. Electrical work
Function table
Select unit number 00
Mode Settings
Mode No.
Setting no. Initial setting Setting
Wired remote
controller
(RF thermostat)
Power failure automatic recovery
(AUTO RESTART FUNCTION)
Not available
01
(101)
1
Available 2
Indoor temperature detecting Indoor unit operating average
02
(–)
1
Set by indoor unit’s remote controller 2
Wired remote controller’s internal sensor 3
LOSSNAY connectivity Not Supported
03
(103)
1
Supported (indoor unit is not equipped with outdoor-air intake) 2
Supported (indoor unit is equipped with outdoor-air intake) 3
Power voltage 230 V
04
(104)
1
208 V 2
Select unit numbers 01 to 03 or all units (AL [wired remote controller]/07 [wireless remote controller])
Mode Settings
Mode No.
Setting no. Initial setting Setting
Wired remote
controller
(RF thermostat)
Filter sign 100 Hr
07
(107)
1
2500 Hr 2
No lter sign indicator 3
Fan speed Standard (PLH/PLA)/Silent (PCH/PCA)
08
(108)
1—
High ceiling
1
(PLH/PLA)/Standard (PCH/PCA) 2
High ceiling
2
(PLH/PLA)/High ceiling (PCH/PCA) 3
No. of air outlets 4 directions
09
(109)
1—
3 directions 2
2 directions 3
Installed options (high-performance lter) Not supported
10
(110)
1—
Supported 2—
Up/down vane setting No vanes
11
(111)
1—
Equipped with vanes (vanes angle setup
1
)2
Equipped with vanes (vanes angle setup
2
)3
Loading ...
Loading ...
Loading ...