Electricalspecications
MODEL
MFZ-KJ09NA
MFZ-KJ12NA
MFZ-KJ15NA MFZ-KJ18NA
INDOORUNIT
Powersupply(V,PHASE,Hz) 208/230,1,60
Min.CircuitAmpacity (A) 1.0
Fanmotor(F.L.A.) (A) 0.62 0.72
OUTDOORUNIT
Powersupply(V,PHASE,Hz) 208/230,1,60
Max.Fusesize(timedelay)(A) 15 20
Min.CircuitAmpacity (A) 11 16
Fanmotor(F.L.A.) (A) 0.50 0.93
Compressor
(R.L.A.) (A) 8.2 12.0
(L.R.A.) (A) 10.3 15.0
Controlvoltage
Indoorunit-Remotecontroller:(Wireless)
Indoorunit-Outdoorunit:DC12-24V(Polar)
Pipe
Outside
diameter
Minimum
wallthick-
ness
Insulation
thickness
Insulation
material
inch(mm)
Forliquid MFZ-KJ09/12/15/18NA 1/4(6.35)
0.0315
(0.8)
5/16(8)
Heatresistant
foamplastic
0.045Specic
gravity
Forgas
MFZ-KJ09/12NA 3/8(9.52)
0.0315
(0.8)
5/16(8)
MFZ-KJ15/18NA 1/2(12.7)
0.0315
(0.8)
5/16(8)
Limits
Pipelength
MFZ-KJ09/12NA 65ft.(20m)max.
MFZ-KJ15/18NA 100ft.(30m)max.
Heightdifference
MFZ-KJ09/12NA 40ft.(12m)max.
MFZ-KJ15/18NA 50ft.(15m)max.
No.ofbends 10max.
Pipelength
Upto25ft.(7.5m) Noadditionalchargeisrequired.
Exceeding25ft.(7.5m)
Additionalchargeisrequired.
(Refertothetablebelow.)
Refrigeranttobe
added
MFZ-KJ09/12NA 1.08ozeach5ft.(20g/m)
MFZ-KJ15/18NA 1.62ozeach5ft.(30g/m)
1-3. SPECIFICATIONS
1-3-1. POWER SUPPLY AND INDOOR/OUTDOOR
WIRE CONNECTION
• Powershouldbetakenfromanexclusivebranchedcircuit.
•
Wiringworkshouldbebasedonapplicabletechnicalstandards.
• Wiringconnectionsshouldbemadefollowingthediagram.
• Securelytightenscrews.
Connecting wires and the ground wire
• Use solid conductor Min.AWG14 or stranded conductor
Min.AWG14.
• Usedoubleinsulatedcopperwirewith600Vinsulation.
• Usecopperconductorsonly.
*Followlocalelectricalcodes.
Power supply cable and ground wire
• Usesolidorstrandedconductor.
KJ09/12NA Min.AWG14
KJ15/18NA Min.AWG12
• Usecopperconductorsonly.
*Followlocalelectricalcodes.
Note:
Whentheindoorunitispoweredfromtheoutdoorunit,depend-
ingonlocalcode,adisconnectswitchneedstobeinstalledtoa
powersupplycircuit.
1-3-2. REFRIGERANT PIPES
• Topreventcondensation,insulatethetworefrigerantpipes.
• Refrigerantpipebendingradiusmustbe4in.(100mm)ormore.
CAUTION
Besuretousetheinsulationofspeciedthickness(tableonthe
right).Excessiveinsulationmaycauseincorrectinstallationof
theindoorunit,andtoolittleinsulationmaycausecondensate
toform.
• Theunit hasaredconnectionsonbothindoorandoutdoor
sides.
• Removethevalvecoverfromtheoutdoorunit,thenconnect
thepipe.
• Refrigerantpipesareusedtoconnecttheindoorandoutdoor
units.
• Becarefulnottocrushoroverbendthepipeinpipebending.
• Refrigerantadjustment...Ifpipelengthexceeds25ft.(7.5m),
additionalrefrigerant(R410A)chargeisrequired.
(Theoutdoorunitischargedwithrefrigerantforpipelengthup
to25ft.[7.5m])
1-2. SELECTING THE INSTALLATION LOCATION
INDOOR UNIT
• Whereairowisnotblocked.
• Whereairspreadsovertheentireroom.
• Rigidwallandatoorwithoutvibration.
• Whereitis notexposedtodirectsunlight.Do not
exposetodirectsunlightalsoduringtheperiodfol-
lowingunpackingtobeforeuse.
• Whereeasilydrained.
• Atadistance3ft.(1m)ormoreawayfrom your
TVandradio.Operationoftheairconditionermay
interferewithradioorTVreception.Anampliermay
berequiredfortheaffecteddevice.
• Inaplaceasfarawayaspossiblefromuorescent
andincandescentlights.Inordertomaketheinfrared
remotecontroloperatetheairconditionernormally.
Theheatfromthelightsmaycausedeformationor
theultravioletmaycausedeterioration.
• Wheretheairltercanberemovedandreplaced
easily.
• Whereitisawayfromtheotherheatorsteamsource.
REMOTE CONTROLLER
• Whereitiseasytooperateandeasilyvisible.
• Wherechildrencannottouchit.
• Selectthepositionwheretheindoorunitcanreceive
thesignalfromtheremotecontrollerproperly.Check
thatsignalsfromtheremotecontrolleraresurelyre-
ceivedbytheindoorunitfromthatposition(‘beep’or
‘beepbeep’receivingtonesounds).Afterthat,attach
remotecontrollerholdertoapillarorwallandinstall
wirelessremotecontroller.
Note:
Inrooms where inverter type uorescent lamps are
used, the signal from the wireless remote controller
maynotbereceived.
OUTDOOR UNIT
• Whereitisnotexposedtostrongwind.
• Whereairowisgoodanddustless.
• Whererainordirectsunlightcanbeavoidedasmuch
aspossible.
• Whereneighbours are not annoyed by operation
soundorhotair.
• Whererigidwallorsupportisavailabletoprevent
theincreaseofoperationsoundorvibration.
• Wherethereisnoriskofcombustiblegasleakage.
• Wheninstallingtheunitatahighlevel,besureto
securetheunitlegs.
• Whereitisatleast10ft.(3m)awayfromtheantenna
ofTVsetorradio.Operationoftheairconditionermay
interferewithradioorTVreceptioninareaswhere
receptionisweak.Anampliermayberequiredfor
theaffecteddevice.
• Installtheunithorizontally.
• Pleaseinstallitinanareanotaffectedbysnowfall
orblowingsnow.Inareaswithheavysnow,please
install a canopy, a pedestal and/or some bafe
boards.
Note:
Itisadvisabletomakeapipingloopnearoutdoorunit
soastoreducevibrationtransmittedfromthere.
Note:
Whenoperatingtheairconditionerinlowoutside
temperature,besuretofollowtheinstructions
describedbelow.
• Neverinstalltheoutdoorunitinaplacewhereitsair
inlet/outletsidemaybeexposeddirectlytowind.
• Topreventexposuretowind,installtheoutdoor
unitwithitsairinletsidefacingthewalland
abafe
boardontheairoutletside.
Avoidthefollowingplacesforinstallationwhereair
conditionertroubleisliabletooccur.
• Whereammablegascouldleak.
• Wherethereisanexcessiveamountofmachine
oilintheair.
• Whereoilissplashedorwheretheareaislled
withoilysmoke(suchascookingareasandfac-
tories,inwhichthepropertiesofplasticcouldbe
changedanddamaged).
• Saltyplacessuchastheseaside.
• Wheresuldegasisgeneratedsuchashotspring,
sewage,wastewater.
•
Wherethereishigh-frequencyor wireless equip-
ment.
• WherethereisemissionofhighlevelsofVOCs,
including phthalate compounds, formaldehyde,
etc.,whichmaycausechemicalcracking.
JG79Y071H02_en.indd 2 2016/01/21 13:19:59