Inspect All Fasteners
Fasteners can loosen with normal use. Inspect all nuts, bolts, screws, and other
fasteners to make sure they are tight and installed correctly.
Be sure to check fasteners at bolted joints to make sure the connections are
secure. If a fastener is loose but in good condition, retighten it. If you are
concerned about the integrity of the fastener, remove it, clean the threads, and
inspect it for any damage such as cracks, bad threads, corrosion, or rust.
Reinstall the fastener if it appears to be in good condition. Otherwise, remove
the equipment from service until a new fastener can be installed properly. You
can order new fasteners from Customer Support. For additional information,
refer to Obtaining Service.
Annual Maintenance
Perform these tasks on an annual basis, as appropriate for your equipment:
Shroud removal.
Weight stack annual maintenance.
Inspect and lubricate pop pins.
Linear ball bearing maintenance.
Weight Stack Annual Maintenance
Once a year, Precor recommends disassembling the weight stack to clean and
inspect it thoroughly.
Carefully remove the cable and guide rods from the weight stack.
Completely disassemble the weight stack in a well-ventilated area, away
from the exercise floor.
Inspect weight plates and clean them thoroughly. Cracked or broken
plates should be replaced immediately (refer to Obtaining Service to
purchase replacements). Clean each plate individually and inspect guide
bushings.
Inspect the bushings of the top weight plate and each individual weight
plate, and replace a plate if it is excessively worn or broken.
Clean the selector stem and inspect it for wear and damage.
Reassemble the weight stack.
Wipe down the weight stack enclosures (shrouds) with a damp cloth as
needed. Inspect all fasteners to make sure the shroud is securely mounted.
Important: Precor recommends that you replace worn and damaged cables during
routine maintenance. It is recommended that all cables be replaced annually.