3.4.2 Mounting the Installation Plate to the Wall (SRC24, SRC36)
Follow this procedure and best practices when mounting the indoor units plate to a wall.
1. Use the provided screws, mount the installation plate horizontally by aligning the centerline using a
leveling tool, Figure3-11.
Figure 3-11
Installation-plate screws for SRC24 and SRC36
2. Observe the left and right rear piping clearance when drilling into the wall, Figure3-12.
Figure 3-12 Piping clearance for SRC24 and SRC36 plate
!
WARNING
Risk of electrical shock. Can cause injury or death.
When choosing a location for the wall-mount plate, be sure to take into consideration routing of
wiring for power outlets within the wall. Avoid contact with hazardous voltage wiring.
Use caution
when drilling holes through the walls for the purposes of piping connections.
Refer to 3.4.3 - Drilling a Piping Hole in the Wall, as you following the plate-installation
procedure.
NOTE
Select the location carefully. Unit should be anchored to a strong wall to
prevent unnecessary vibration.
Chassis
Hook
Type "A" Screws
Left rear piping Right rear piping
1-11/16
4-11/32
4-11/16
Unit: Inch
1-11/16
30-
11/16
13-
3/16